If the cut on cut off is 40 60 psi is what the factory setting is on the pressure switch.
Dwyer pressure switch adjustment.
For air and non combustible compatible gases series 1900 switches have set.
1910 00 switch pdf manual download.
Here we are discussing setting the water pressures at which a water pump will turn on to get more water and off to stop pumping water from the water source into the water tank.
Clear easy to read and convenient external setpoint adjustment.
Ul and csa listed fm approved for general service these.
1910 0 1910 1 1910 5 1910 10 1910 20.
20 pa up to 16 w c.
External adjustment visible dial hermetically sealed snap or mercury switch gas pressure differential pressure switch is used with air and other compatible gases.
External adjustment visible dial hermetically sealed snap or mercury switch gas pressure differential pressure switch is used with air and other compatible gases.
Applications include natural manufactured or lp gas.
Our most popular series 1900 compact low differential pressure switch combines advanced design and precision construction to make these switches able to perform many of the tasks of larger costlier units.
You can adjust the differential by turning the short adjusting nut on the pressure switch clockwise to increase or counter clockwise to decrease the differential it s seldom required and i suggest you not tamper with this setting unless you know what.
The adps is available with settings from 0 08 wc 20 pa up to 20 wc 5000 pa.
Applications include natural manufactured or lp gas.
The dual scaled adjustment knob in inches water column and pascals allows changes to the switching pressure to be made without a pressure gage.
The dual scaled adjustment knob in inches water column and pascals allows changes to the switching pressure to be made without a pressure gage.
1900 series pressure switch.
A 20 psi differential is standard and recommended.
View and download dwyer instruments 1910 00 installation and operating instructions online.
Water well pump pressure control switch adjustment.
The series adps adjustable differential pressure switch is designed for pressure vacuum and differential pressures.
Series 1630 large diaphragm pressure switches visual set point adjustment in 5 standard ranges 0 05 to 12 w c.
Clear easy to read and convenient external setpoint adjustment.
The edps is available with settings from 0 08 w c.
Designed for air conditioning service they also serve many fluidics refrigeration oven and dryer applications.
How to set the water pump cut in and cut out pressures.
The cut on pressure is the low pressure that starts the pump and the cut off pressure is the high pressure that turns off the pump.
The switch is preset with both the cut on and cut off pressure.
The series edps adjustable differential pressure switch is designed for pressure vacuum and differential pressures.